Daikin RZUR-Q · Packaged — representative product image
Representative image · English catalogue, PDF 2 ↗

RZUR400QY1

Daikin · Cooling only · Inverter air cooled Packaged · R-410A

RZUR400QY1 is a Daikin outdoor unit in the RZUR-Q · Packaged series, cooling only · inverter air cooled packaged · r-410a type. Its reference system cooling capacity (*1) is 46.9 kW according to catalogue PCTPMT2309.

Reference system cooling capacity
46.9 kW
Power supply
3 Phase, 380–415 V, 50 Hz
Dimensions (H×W×D)
1,657×930×765 mm
Weight
260 kg
Data extracted from the English catalogue; not all specifications have been manually verified. Check the source before use. Source & notes →
Open comparison tool →

RZUR400QY1 specifications

RZUR400QY1 specifications · PCTPMT2309
System configuration 1 specifications
Unit combinationFDR400QY1 + RZUR400QY1
Rated capacity 5 specifications
Cooling capacity (19.5°CWB) *1 *3 · kW46.90
Cooling capacity (19.5°CWB) *1 *3 (Max.) · kW46.90 (47.48)
Cooling capacity (19.5°CWB) *1 *3 (Max.) · Btu/h160,000 (162,000)
Cooling capacity (19°CWB) *2 *3 (Max.) · kW46.30 (46.90)
Cooling capacity (19°CWB) *2 *3 (Max.) · Btu/h158,000 (160,000)
Electrical & efficiency 6 specifications
System power consumption (19.5°CWB) *1 *3 · kW15.79
System power consumption (19°CWB) *2 *3 · kW15.69
CSPF (19°CWB) *24.12
Power supply3 Phase, 380–415 V, 50 Hz
Compressor · TypeHermetically sealed scroll type
Compressor · Motor output · kW(3.5×1)+(3.5×1)
Airflow & sound 2 specifications
Air flow rate (H) · m³/min257
Sound level *4 · dB(A)60
Dimensions & weight 3 specifications
Casing colourIvory White
Dimensions (H×W×D) · mm1,657×930×765
Machine weight · kg260
Piping & refrigerant 6 specifications
Refrigerant · TypeR-410A
Refrigerant charge · kg8.2
Refrigerant piping · Liquid · mmØ 12.7 (Brazing)
Refrigerant piping · Gas · mmØ 28.6 (Brazing)
Max. piping length · m70 (equivalent length 90 m)
Max. level difference · m50
Operating conditions 1 specifications
Operation range · °CDB10 to 49

Catalogue source & rating conditions

Values are taken from PCTPMT2309, PDF page 4 (printed page 6). Daikin Inverter Air Cooled Packaged · PCTPMT2309.

Rated performance depends on test conditions and system combinations. Check the source notes when selecting equipment or comparing series.

Read original source notes (English)
Note: *1. Indoor temp.: 27°CDB, 19.5°CWB / outdoor temp.: 35°CDB, 24°CWB / Equivalent piping length: 7.5 m, level difference: 0 m. *2. Indoor temp.: 27°CDB, 19°CWB / outdoor temp.: 35°CDB, 24°CWB / Equivalent piping length: 7.5 m, level difference: 0 m. *3. Capacity is net, including a deduction for cooling for indoor fan motor heat. *4. Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation these values are normally somewhat higher as a result of ambient conditions and oil recovery mode. Consider location and soundproofing measures near residences. *5. The value is the external static pressure with standard pulley. *6. Max. 40 m if the outdoor unit is lower than the indoor unit. Packaged system: cooling capacity, system power consumption and CSPF refer to the stated indoor/outdoor pairing. Outdoor model pages use the FDR pairing as the reference, except the RZUR-P models, which use their respective FVGR-P pairings. Parenthetical capacities are the source maximum values. Optional equipment is shown separately in the PDF.
View catalogue page · PDF 4

The original page preserves symbols, merged cells and accessories; not every accessory shown is supplied with the unit.

Original English catalogue, PDF page 4
Read all text from this page and its facing page
Note: *1. Indoor temp.: 27°CDB, 19.5°CWB / outdoor temp.: 35°CDB, 24°CWB / Equivalent piping length: 7.5 m, level difference: 0 m. *2. Indoor temp.: 27°CDB, 19°CWB / outdoor temp.: 35°CDB, 24°CWB / Equivalent piping length: 7.5 m, level difference: 0 m. *3. Capacity is net, including a deduction for cooling for indoor fan motor heat. *4. Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation these values are normally somewhat higher as a result of ambient conditions and oil recovery mode. Consider location and soundproofing measures near residences. *5. The value is the external static pressure with standard pulley. *6. Max. 40 m if the outdoor unit is lower than the indoor unit. Packaged system: cooling capacity, system power consumption and CSPF refer to the stated indoor/outdoor pairing. Outdoor model pages use the FDR pairing as the reference, except the RZUR-P models, which use their respective FVGR-P pairings. Parenthetical capacities are the source maximum values. Optional equipment is shown separately in the PDF.

Catalogue article on VRV.vn ↗ · Original English PDF on VRV.vn ↗

Daikin VRV System Design & Installation

Công Ty Cổ Phần Điều Hòa VRV Joint Stock Company specializes in the design and installation of Daikin VRV central air conditioning systems for factories, buildings, and luxury villas. For inquiries, please contact Công Ty Cổ Phần Điều Hòa VRV at: https://vrv.com.vn/